Troubleshooting and Service Checklist
Problem
Cause
Solution
Valve does not change
or cycle to next zone or
outlet.
Debris or foreign objects preventing
proper movement of stem and disk
assembly.
• Remove valve top and check for foreign objects.
Clean build-up from walls as necessary.
• Check for freedom of movement of stem and
disk assembly up and down over the center pin
in bottom of valve. Scale deposits may build up
on the pin and hold stem and disk assembly
down. Clean pin and again check for freedom of
movement.
Disk may have expanded and is rub-
bing against inside walls of body.
• Replace disk and clean build-up from walls of
valve as necessary.
Restriction of flow causing pressure
in valve to build up, preventing valve
from cycling.
• Be sure that all operating outlets are not capped
and that the flow to operating zones is not
restricted in any manner.
• The backflow of water from uphill lines may be
preventing the valve from cycling properly. If the
valve cannot be placed close to the high point
of the system, a check valve should be installed
near the valve in the outlet line that runs uphill
from the valve.
Water comes out of all
the valve outlets.
Stem and disk assembly not seating
properly on valve outlet.
• Check for sufficient water flow. A minimum of 15
GPM is required to properly seat the disk.
• Remove the valve top and clean the inside walls
as necessary to ensure that nothing is interfering
with the up and down movement of the stem and
disk assembly inside the valve.
• Make sure that the operating outlets are no
capped and that the flow to the operating zones
is not restricted in any manner.
• Replace disk if necessary.
Valve skips outlets or
zones.
This will case the valve to cycle
quickly several times, skipping one
or more zones.
• The stem and disk assembly is being advanced
past the desired outlet.
• Ensure that the correct cam for the desired
number of zones is installed and that the outlet
lines are installed to the correct outlet ports of
the valve.