Pump Fed Application
For direct pump-fed installations, the 6000 Series Automatic Multizone Valve is directly connected to the discharge side of the pump and is cycled from
one zone to the next by turning the pump off and on. See the Active Zone Diagram below in Figure 1.
Technical Specifications
Valve Top and Body Construction:
Die cast
Valve Bottom Construction:
ABS High strength plastic
Flow Range:
15-100 GPM
Inlet:
Threaded 1½" NPT
Outlets:
Allows for 1½" PVC pipe slip and glue connection
6400 Series 4 Outlet Valve
Flow (GPM)
15
20
30
40
50
60
70
80
90
100
PSI Loss
2.0
2.5
3.0
3.5
4.0
5.0
6.0
7.5
9.0
10.0
Flow Characteristics:
6600 Series 6 Outlet Valve
Flow (GPM)
15
20
30
40
50
60
70
80
90
100
PSI Loss
2.0
3.0
3.5
4.0
5.0
6.0
7.5
9.0
10.0 11.0
Parts List
Parts List
REF NO. DESCRIPTION
PART NO.
1
4 Outlet valve top
153295
6 Outlet valve top
153296
2
Valve body seal
150495
3
Rubber flap disc
153268
4
Stem with .032 spring
153269
Stem with .028 spring
153270
5
Stem / disk assy. w/ .032 spring
019141
Stem / disk assy. w/ .028 spring
019142
6
4 Outlet valve bottom
153271
6 Outlet valve bottom
153272
7
Vacuum Breaker assy.
151258
8
Two zone, 4 outlet cam
019136
Three zone, 4 outlet cam
019137
Four zone, 4 outlet cam
019138
Five zone, 6 outlet cam
019139
Six zone, 6 outlet cam
019140
9
Valve bottom screws (6) (10-24 x
3/4 Phil Pan SS
153273
10
Valve top screws (8) (10-24 x 5/8
Stlt.phst SS
153274
11
Cam retaining screws (2) (6 x 1/2
Phil Pan SS)
153275
12
Valve bottom S.S Pin (¼" dia.)
153073
Figure 1