28

29

Troubleshooting

The following troubleshooting guide can help identify a problem and provide a solution.

Inspect your waste handling system before you contact an authorized service representative.

System will not turn ON.

Main Power Supply OFF

Remote Control Cabinet 3A

push button breaker tripped.

Remote control cabinet Main Circuit

Breaker Switch OFF.

Safety Switch not closed or

defective.

Start/Stop Station switch not operated

or defective.

Main water supply valve is closed.

Remote control cabinet Main Circuit

Breaker Switch OFF.

Pulper water level pressure switch

mis-adjusted or defective.

Water solenoid valve defective.

Drain valve or water extractor

drain/overflow open.

Pulper water level pressure switch

mis-adjusted or defective.

Pressure switch tubing or air

snubber is clogged or broken.

Water solenoid valve defective.

Water extractor screen clogged

and/or auger brush defective.

Metal object in tank.

Cutting blades hitting cutting blocks.

Waste input lacks paper

Extractor drain/overflow restricted.

Compression Cone mis-adjusted.

Remote Control Cabinet Main Circuit

Breaker Switch has tripped. Handle

is in the TRIP position.

Main Power Supply to system OFF.

Problem

Cause(s)

Solution(s)

Turn on or reset breaker.

Push to reset 3A breaker

Rotate Handle to ON Position.

Check/replace pulper and/or

water extractor safety switch.

Push Start push button to run.

Open valve.

Adjust or replace switch.

Clean or replace snubber/tubing.

Repair or replace solenoid valve.

Remove object.

Contact service agent to adjust.

Close drain valve, rotate drain/overflow

handle to closed position.

Feed cardboard into pulper to thicken slurry.

Shut down system and contact service agent.

No fill water to pulper.

Rotate Handle to ON Position.

Pulper fills constantly.

Adjust or replace switch.

Repair or replace solenoid valve.

Clean extractor screen and/or

contact service agent.

Banging noise coming from pulper.

Pulp discharge is too wet.

Check drain/overflow in water extractor.

System shuts down unexpectedly.

Turn handle CCW to RESET then CW to

OFF and contact service agent.

Check Main Power Supply Breaker.