Pulper/water extractor electrical controls, Pulper/water extractor - initial start-up, B : 3 amp manual reset circuit breaker – CHAMPION P7-30 Manual User Manual
Page 23: C : red power on indicator light, D : optional deodorizer injector on/off switch, F : optional flushing valve on/off selector switch
14
15
Pulper/Water Extractor - Initial Start-up
Pulper/Water Extractor Electrical Controls
POWER MUST BE TURNED OFF UNTIL ALL MECHANICAL CHECKS ARE COMPLETE.
3
CIRCUIT BREAKER
POWER - ON
OFF
RESET
LOCK
TRIP
O
ON
I
DEODORIZER
FLUSHING V
ALVE
OFF
ON
ON
OFF
RESET
LOCK
OFF
TRIP
ON
DELA
Y ST
OP
START
STOP
Remote Control Cabinet shown with deodorizer, delay stop, and flushing valve
options and the system Start/Stop Station located at the top of the water extractor.
The Remote Control Cabinet offers
the following controls:
A: ON/OFF manual reset breaker
switch.
Rotate handle fully CW to turn
power ON. Rotate handle fully
CCW to reset tripped breaker
and to lock-out breaker to service.
B: 3 amp manual reset circuit
breaker.
Push reset button in if 120VAC control
circuit breaker trips.
C: Red POWER ON indicator light.
Indicator illuminates when ON/OFF
breaker switch (A) is in the ON position.
D: Optional Deodorizer Injector
On/Off switch.
Push toggle switch ON to run the Injector.
The injector speed-control is located
inside the remote control cabinet. Amount
of deodorizer injected depends on the
customer's requirements.
E: Optional Delay/Stop switch
with adjustable 6-minute timer.
Push the Delay/Stop switch. Depending
on the timer setting, the system will
STOP after the preset time DELAY.
F: Optional Flushing Valve On/Off
selector switch.
Turn the selector switch ON and the
water extractor and/or pulper flushing
system will operate.
G: System START/STOP station
located on the water extractor.
Push the Start push button and the
waste handling system will run. Push
the Stop push button and the system
will shut-off.