Installation

Electrical Connections - 380V/50/3

ATTENTION

A qualified electrician must connect the main incoming power to the dishwasher in accordance with all
local codes and regulations or in the absence of local codes in accordance with the National Electrical
Code.

Standard Dishwashers are shipped from
the factory for 3-phase operation.
To connect the dishwasher for 3-phase
operation:

1.

Remove the top-mounted control
cabinet cover and locate the main
terminal block in the left-rear
corner of the cabinet.

2.

Refer to the Machine Electrical
Connection Data Plate
located
near the main terminal block and
make sure that the incoming
power supply matches the
machine's electrical requirements.

3.

Connect the incoming 3-phase
power as shown in the illustration
to the right. The incoming power
must be a 4-wire supply which
includes a current carrying neutral
and ground.

4.

Re-install the control cabinet
cover.

WARNING:

Electrocution or serious injury may result when working on an
energized circuit.

Disconnect power at the main breaker or service disconnect
switch before working on the circuit.

Lock-out and tag the breaker to indicate that work is being
performed on the circuit.

Three Phase Operation

Main Terminal Block

Main Terminal Block Location

THREE PHASE

POWER CONNECTION

380V/50/3

LINE IN

L1

L2

L3

N

GRD