beautypg.com

Oldback, Programming, Reating a – Carbolite 3216P1/P5 User Manual

Page 10: Rogram, 5 programming

background image

Programming

10

MC18-GB

– v1.04


Single Offset
If a constant offset is required acro

ss the temperature range, set the required “High Point”

(

PNT.HI) and “Low Point” (PNT.LO) to the required values (not the same), then set the “low

Offset” (OFS.LO) and “High Offset” (OFS.HI) to the same value.

Caution! - Do not make

PNT.LO and PNT.HI the same value as the controller will

not work correctly and could cause your furnace or oven to overheat.

4.7

Holdback


If the temperature ramp rate of the program is quicker than the furnace or oven can achieve,
the program will wait until the temperature of the furnace or oven catches up.
e.g. If a Holdback value of 10 is set and the program is set to ramp to a setpoint of 600°C,
the program will reach 600°C, then go into an hold state; the hold indicator will light until the
furnace or oven temperature reaches 590°C, the program will then continue to control
again.
The hold back will only apply once per Segment, therefore when control has been re-
established, the hold back will not apply again to that segment, even if the furnace or oven
temperature go outside the hold back band.

Holdback can only be accessed in supervisor level (level 2) by scrolling with the Scroll

until the display shows

H.BACK : Use the Up

Down

to select the

required Hold Back value.
If a multi programmer is used, each program can have its own Holdback value assigned to
it.

Note:

When a Holdback is set, each segment used must have a Ramp Rate assigned

to it, in order for it to be recognised by the program.

5 Programming

5.1

Creating a Program

Programs can be created in level 1 or level 2 of the 3216 P1 and 3216P5. Each program
contains 8 Ramp/Dwell pairs.

Note:
A currently active program cannot be altered. Go into reset mode before starting to create or
modify a program


Program Number (3216 P5 Only)
Press scroll

until the display shows

PROG <PROGRAM NUMBER.> Select the program

number.