5.5 Thermocouple Replacement

Disconnect the furnace from the supply, and remove the back panel. The thermocouple and its
sheath are on the exhaust (right-hand) side.

Make a note of the thermocouple connections. The negative leg of the thermocouple is marked
blue. Compensating cable colour codings are:

negative

positive (type K)

white

green

Disconnect the thermocouple from its terminal block.

Withdraw the thermocouple from its sheath and remove any broken bits of thermocouple.

Insert the new thermocouple into position, restoring any removed porcelain spacers, and ensuring
correct polarity.

Re-assemble the furnace.

5.6 Element Replacement

See section 5.2 - wearing a face mask is recommended.

The element is supplied complete with the surrounding stainless steel half-cylindrical inner

chamber.

Disconnect the furnace from the electrical supply, and remove the back panel. Work with the

furnace lid open, with no vessel in place.

Make a careful note of the colours and positions of all the electrical connections to the inner

cylindrical chamber and thermocouple.

Disconnect the thermocouple and element connections from their terminal blocks.

Remove the thermocouple. It may also be necessary to remove the thermocouple sheath: loosen

the retaining screw and withdraw the sheath.

Supporting the weight of the inner chamber, loosen 4 screws holding brackets to the top plate;

loosen and remove 4 screws holding the chamber to the brackets.

Lift out the inner chamber.

Fit the new chamber by reversing the process. Take care to make all connections to the correct

terminals. Do not overtighten the connectors in porcelain terminal blocks.

Let the furnace heat up at its maximum rate to 900°C without interruption, and then soak for 1

hour. Fumes may be emitted: this should be done in conditions of good ventilation.

Check that the furnace is controlling properly to rule out the possibility that the element failed

because of a fault in the control system.

If you have any problems with this procedure, please contact our service division.