beautypg.com

Fuses & power settings, On 8.2, 8 fuses & power settings – Carbolite EZS Series User Manual

Page 23

background image

E range

MF65-1.01

23

23

8 FUSES & POWER SETTINGS

8.1 Fuses -
For wiring diagram information on F1 and F2 refer to Figure 7-1 page 22, for fuse values refer to Table
8-2
and Table 8-3.

Table 8-1. Fuse type information.

F1

Internal
supply fuses

Fitted to all E range models.
Each circuit has 2 fuses, in most cases fitted to the
EMC filter board.

32mm x 10mm type F

F2

Auxiliary
circuit fuses

Fitted to all E range models.
In most cases fitted to the EMC filter board.

2 Amps
On board: 20mm x 5mm type F
Other: 32mm x 6mm type F

Customer
fuses

Required to protect customer supply circuit and
lead.

See rating label for amperage; see
Table 8-2 and Table 8-3for
minimum supply and fuse ratings.

8.2 Table of internal fuse and external supply ratings.

All furnace models are single phase. Most models have internal fusing as in the Table 8-2 and
Table 8-3 below. Customers should check the rated amps in the tables below and make sure that
their electrical supply is rated accordingly (or at least the next fuse size up from the rated amps
table). Customers should also fit external fusing if their particular model of furnace does not have
internal fuses. The function of the customer’s (external) fuse is to protect the customer’s wiring.
All electrical connections other than where it is just a simple plug into an existing correctly rated
electrical supply must be carried out by an electrically competent person with the correct
certification to meet local legislation.


Table 8-2. Fuse ratings for 100 to 110V Supply Voltages

Model

Power

rating

(Watts)

Internal

supply

fuses F1

Internal

instrument

fuses F2

Furnace

rated amps

1-phase

100-110V

Single

Zone

EHA/EVA/EST/EVT 12/150

750

2x10A

2x2A

7A

EHA/EVA/EST/EVT 12/300

1480

2x16A

2x2A

14.5A

EHA/EVA/EST/EVT 12/450

1960

2x20A

2x2A

19A

EHA/EVA/EST/EVT 12/600

2480

2x25A

2x2A

24A

Three

Zone

EHC/EVC/EZS/EVZ 12/450

1960

2x20A

2x2A

19A

EHC/EVC/EZS/EVZ 12/600

2480

2x25A

2x2A

24A

Table 8-3. Fuse ratings for 200 to 240V Supply Voltages

Model

Power

rating

(Watts)

Internal

supply

fuses F1

Internal

instrument

fuses F2

Furnace

rated amps

1-phase

200-240V

Single

Zone

EHA/EVA/EST/EVT 12/150

750

2x4A

2x2A

3.5A

EHA/EVA/EST/EVT 12/300

1480

2x10A

2x2A

7.1A

EHA/EVA/EST/EVT 12/450

1960

2x10A

2x2A

9.5A

EHA/EVA/EST/EVT 12/600

2480

2x12A

2x2A

12A

Three

Zone

EHC/EVC/EZS/EVZ 12/450

1960

2x10A

2x2A

9.5A

EHC/EVC/EZS/EVZ 12/600

2480

2x12A

2x2A

12A

This manual is related to the following products: