beautypg.com

Fuses & power settings – Carbolite TZF Series User Manual

Page 14

background image

14

MF12 3.12

Independent Zones (control method C)

When this is ordered there are three independent thermocouples (instead of the four shown)
connected to the three controllers; the words “master” and “slave” may be replaced by “centre”

and “end”.

7.4 Control by Broadcast comms (control method B)

When this is ordered there are three independent thermocouples (instead of the four shown)
connected to the three controllers; the controllers are linked together (not shown), and remain

“master” and “slave”.

The communication between the controllers of the Eurotherm 3000 series is known as Broadcast
comms. The wiring connections between the controllers are as follows:

8.0 F

USES

&

P

OWER

S

ETTINGS

8.1 Fuses

F1-F3: refer to the example circuit diagram.

F1

Internal
supply
fuses

Fitted if supply cable fitted.
Fitted on board to some types of EMC filter.

on-board and up to 16 Amps:
32mm x 6mm type F
other: GEC Safeclip

F2

Auxiliary
circuit
fuses

Fitted on board to some types of EMC filter.
May be omitted up to 25Amp/phase supply
rating.

2 Amps glass type F
On board: 20mm x 5mm
Other: 32mm x 6mm

F3

Heat Light
fuses

May be omitted up to 25 Amp/phase supply
rating.

2 Amps glass type F
32mm x 6mm

Customer
fuses

Required if no supply cable fitted.
Recommended if cable fitted.

See rating label for amperage;
see table below for fuse rating.

Access to internal fuses is by removal of the back panel of the furnace base or control box.

Model

phases

Volts

Supply
Rating

Volts

Supply
Rating

TZF 12/38/400

1-phase

200-240

7A

110-120

12.5A

TZF 12/65/550

1-phase

200-240

10A

110-120

20A

TZF 12/65/550

2- or 3-phase + N

380/220 - 415/240

5A

TZF 12/75/700

1-phase

220-240

12.5A

110-120

25A

TZF 12/75/700

1-phase

208

15-16A

100

30-32A

TZF 12/75/700

2- or 3-phase + N

380/220 - 415/240 7A

TZF 12/100/900 1-phase

200-240

20A

110-120

40A

TZF 12/100/900 2- or 3-phase + N

380/220 - 415/240 15-16A

other models or voltages: check the rating label for details of the supply.

8.2 Power Settings

HD

HE

HF

HD

HE

HF

HD

HE

HF

master

slave

slave