Specifications – Carbolite GVC Series User Manual
Page 21
MF48 -1.18
21
9.0 S
PECIFICATIONS
9.1 Models Covered by this Manual
GHA models – horizontal single-zone tube furnaces with controls in integral base
GVA models – versatile single-zone tube furnaces with controls in integral base
GHC models – horizontal three-zone tube furnaces with controls in integral base
GVC models – versatile three-zone tube furnaces with controls in integral base
All models have cylindrical elements with wire formed in the surface of the insulation material.
All models have can accept work tubes up to a maximum outside diameter of 170mm.
All models have a maximum operating temperature of 1200°C (1100° continuous).
Model names are of the type “GHA 12/300” where 300 is the heated length. Sizes range from
300mm heated length (GHA/GVA) or 450mm (GHC/GVC) to 1200mm (all models).
Heated
Length
Max.
Power
Minimum
work tube
length
Type C
work tube
Type D
work tube
(mm)
(W)
(mm)
(mm)
(mm)
300
2340
480
600
900
450
3120
630
750
1050
500
3900
780
900
1200
750
4680
930
1050
1350
900
5460
1080
1200
1500
1050
6240
1230
1350
1650
1200
7020
1380
1500
1800
1500
8580
1530
1800
2100
Work tubes may be supplied in any commercially available size up to the maximum of 170mm
o/d. Type C protrudes about 40mm from each end of the furnace (from the end guards), while type
D allows for the fitting of gas seals or other attachments.
9.2 Environment
The furnaces contain electrical parts and should be stored and used in indoor conditions as
follows:
temperature:
5°C - 40°C
relative humidity:
maximum 80% up to 31°C decreasing linearly to 50% at 40°C
Carbolite reserves the right to change specifications without notice.