beautypg.com

Lso 7.6, S shown in 7.5, G range – Carbolite GVC Series User Manual

Page 16

background image

G range

16

MF48 -1.18

3-phase without neutral (delta)

In most instances this diagram does not apply. See 7.7. It may apply if non-standard models are
ordered.

7.5 Higher Voltages

For 254V or above 1-phase or 440/254V or above 3-phase an isolating transformer is fitted in the
control circuit after the F2 fuses.

This addition may be applied to diagrams 7.1, or 7.3.

7.6 Three-Zone models

The element circuit in the 3-zone versions remains the same as in diagrams 7.3, 7.4 or 7.7, but the
control circuit contains three controllers and additional thermocouples. The sub-circuits for the
three control methods referred to in section 3.2 are:

Control type B - the diagram is like C, plus the connections between the controllers indicated in
section 3.2 C.

slave

controller

thermocouples

SSR

master

controller

SSR

SSR

slave

controller

centre

end

end

Control type A

Control type C

slave

controller

thermocouples

SSR

master

controller

SSR

SSR

slave

controller

main

ref.

slave

slave

+

+

+

+

e

l

e

m

e
n

t

(s)

e

l

e

m

e
n

t

(s)

Instrument Switch

coil

temperature

controller

overtemp.

controller

thermocouple

heater

switch

SSR

heat

on

F3

F1

F2

F3

L2

L3

L1

PE

SSR

SSR

F3

heat

on

F3

e

l

e

m

e
n

t

(s)

heat

on

F3

F3

if fitted

thermocouple

contactor

Filter (if fitted)

F2

F2

transformer

Instrument Switch