beautypg.com

Fuses & power settings – Carbolite VMF Series User Manual

Page 15

background image

AAF, GSM, VMF


MF06 3.32

15

8.0 F

USES

&

P

OWER

S

ETTINGS

8.1 Fuses

F1-F3: Refer to the circuit diagrams.

F1

Internal
supply
fuses

Fitted if supply cable fitted.
Fitted on board to some types of EMC filter.

on-board and up to 16 Amps:
32mm x 6mm type F
other: GEC Safeclip

F2

Auxiliary
circuit
fuses

Fitted on board to some types of EMC filter.
May be omitted up to 25Amp/phase supply
rating.

2 Amps glass type F
On board: 20mm x 5mm
Other: 32mm x 6mm

F3

Heat Light
fuses

May be omitted up to 25 Amp/phase supply
rating.

2 Amps glass type F
32mm x 6mm

Customer
fuses

Required if no supply cable fitted.
Recommended if cable fitted.

See rating label for amperage;
see table below for fuse rating.

Model

Phases

Volts

Supply Fuse
rating

AAF 11/3

1-phase

200-240

10A

1-phase

110

20A

AAF 11/7

1-phase
1-phase
1-phase
2-phase+N

220-240
200-208
110-120
380/220-415/240

20A
20A
40A
10A per phase

AAF 11/18

1-phase

220-240

30A

1-phase

200-208

40A

3-phase+N

380/220-415/240

12.5A per phase

3-phase delta

220-240

20A per phase

3-phase delta

200-208

25A per phase

AAF 12/3

1 phase

200 - 240

10A

AAF 12/7

1-phase

220–240

25A

AAF 12/18

1-phase

220-240

30A

1-phase

200-208

40A

3-phase+N

380/220-415/240

12.5A per phase

3-phase delta

220-240

20A per phase

3-phase delta

200-208

25A per phase

GSM 11/8

1-phase
1-phase
1-phase

220-240
200-208
110-120

12.5A
15A or 16A
25A

VMF 10/6

1-phase

220-240

12.5A


8.2 Power Settings

The settings of the power limit parameter

OP.Hi

are as follows.

model volts:

110

200

208

220, 380

230, 400

240, 415

254, 440

AAF 11/3

87

100

98

87

80

73

65

AAF 11/18

100

100

100

100

94

83

AAF 12/3

100

95

85

78

71

AAF 12/7

100

100

100

AAF 12/18

100

100

100

100

94

83

all other models

100

100

100

100

100

89

This manual is related to the following products: