HRF


MLF05-1.23

11

8.0 F

USES

&

P

OWER

S

ETTINGS

8.1 Fuses

F1-F2: Refer to the circuit diagrams.

F1

Internal
supply
fuses

Fitted if supply cable fitted.
Fitted on board to some types of EMC filter.

on-board and up to 16 Amps:
32mm x 6mm type F
later models: 38mm x 10mm
other: GEC Safeclip or Ferraz
to suit supply rating

F2

Auxiliary
circuit
fuses

Fitted on board to some types of EMC filter.

2 Amps glass type F
On board: 20mm x 5mm
Other: 32mm x 6mm

Customer
fuses

Required if no supply cable fitted.
Recommended if cable fitted.

See rating label for amperage;
see table below for fuse rating.

Model

phases

Volts

Supply Fuse
Rating

HRF 7/45

1-phase

220-240

30A or 32A

HRF 7/45

3-phase+N

380/220-415/240

10A/ph

HRF 7/45

3-phase delta

220-240

16A/ph

8.2 Power Settings

For models made for 254 volts or 440 volts the power limit parameter

OP.Hi

may be set to 89%. If

in doubt please contact Carbolite.

For all other models in this manual the power limit parameter

OP.Hi

is set to 100%.

Fan

Motor

Capacitor

BU R R1