Mk-5000g troubleshooting – Barranca Diamond MK-5009G/5013G User Manual
Page 34

34
(F)
Locate Cooling Channels inside
Blade Guard
Cooling Flow Stopped
(A)
Check Cooling Flow
Control Valve is open
(B)
Remove Transfer Tube from
Blade Guard
(C)
Place Water Pump in clean
water source and check for flow
(if no flow go to step G)
“Rodding” cooling channels is performed by removing the flow control valve and then inserting a small wire rod
through the cooling channel inlet, located on the underside of the Blade Guard. The cooling channels should be
“rodded” until each of the outlet ports are open and free of foreign debris.
NOTE:
(D)
Verify Cooling Valve operation
by removing the valve from the
Blade Guard
(E)
Attach the Cooling Valve to the
Transfer Tube to verify flow –
if no flow, replace valve
(G)
Rod Cooling Channels and
recheck flow
(H)
Verify Water Pump suction is
clean and pump impeller is
turning. Pump Impeller is inside
water inlet
(I)
Verify Water Pump drive end is
in the operating position
MK-5000G TROUBLESHOOTING