Axcess Network Receiver Installation Guide User Manual
Page 20
Network Receiver
20
750.001.005 R04
© 2005 AXCESS Inc.
5.
TTL output 1 on valid read, when enabled any read from a tag
will cause TTL 1 to be triggered. Default OFF “16c”
6.
TTL output 2 on valid read, when enabled any read from a tag
will cause TTL 2 to be triggered. Default OFF “17c”
7.
Serial data output, allows the user to disable or enable the RS-
232 or TCP/IP output. Default ON “18c”
8.
Wiegand Activator ID filter, enables or disables the single
Activator ID in the config line (i.e. W = 127). Default ON “19c”
9.
Serial Data format, Sets the serial data format to long or short to
support older versions of the Axcess RFID products. Default
Long “21c”
10.
Diagnostic mode, enables or disables diagnostic mode. If in
diagnostic mode the receiver will output data the Wiegand, Serial
and TCP/IP without checking the Activator ID filter. Default OFF
“22c”
11.
TTL and Wiegand Timers, enables or disables the timers for the
TTL and Wiegand outputs. Default ON “20c”
12.
Wiegand Activator, enables or disables the Wiegand Activator list
.
Default OFF “42c”
D=005 E=005
Time in seconds that the TTL Outputs will go from LOW to High (from
0 V DC to 5 DC). This value can range from 1 to 255 seconds. D is
TTL Output One and E is TTL Output Two. Default 005
I=001
This Receiver ID, this value can range from 001 to 255. Default 001
L=125
The period of time the receiver will not output any additional tag
reads of duplicate tag ID’s, new tag ID’s will still be output, out the
Wiegand port. The above value is 12.5 seconds. Default 125
T=013
The period of time between tag ID’s being output the Wiegand port.
This is buffer is used to prevent the tag ID’s from being sent to fast to
the Wiegand panel. The above value is 01.3 seconds. Default 013
W=127
The Activator ID which data will be output on to the Wiegand port, if
enabled. (by default this list is enabled).