Axcess Network Receiver Installation Guide User Manual
Page 16
Network Receiver
16
750.001.005 R04
© 2005 AXCESS Inc.
Serial Output Format
The default format for Tag data sent out the serial port of the
Receiver is:
R R R A A A F F F T T T T T LF CR
R
= Receiver ID
A
= Activator ID
F
= facility code
T
= Tag ID number
LF
= Line Feed
CR
= Carriage Return
To make the Receiver backwards compatible with AXCESS NT
132 systems, type:
36c
. The serial output will now have the
short format. To return to the long format (default), type:
21c
Optimizing Serial Output
The speed at which the Network Receiver processes data can
be maximized by eliminating extra steps required to output
Wiegand data and check TTL output control settings. Use the
following commands to optimize the serial output:
Command
Action
29c
Turn off Receiver’s Wiegand output
15c
Restore Wiegand output
(Default)
35c
Disable TTL outputs
(If your installation does not require TTL outputs,
the serial output can be optimized by disabling
them. This will also disable Wiegand outputs)
20c
Restore TTL output operations
TIP
When the Network Receiver is sending data via the serial port,
the LED labeled DATA TX will alternately flash from red to green.
Observing this LED on the front of the unit will help in verifying
proper operation of the Receiver
.