Electrical Wiring — 940111 only
1.
Remove the cover on the round box by taking out
the two screws.
Electrical Box
2.
Insert the emergency stop cable through the
empty box connector until the outside jacket just enters
the round box, or is completely inside the connector.
Tighten the two connector screws.
3.
Loosen the two screws that are clamping the foot
switch cable enough to push the hood switch cable into
the box. Tighten the two connector screws.
4.
Remove the screw-on connector from the BLACK
wire of the foot switch and add the BLACK wire from
the hood switch.
Screw connector on tightly.
5.
Join the WHITE wires from all three switches
together with a screw-on connector.
6.
Connect the BLACK wire from the stop switch to
the jumper wire from the outlet using a screw-on con-
nector.
7.
Re-attach the round cover plate and gasket to the
box with the two screws.
Electrical Wiring Assembly
Hood Switch
Cable (Ref)
Box
Mounting
Tab
Stop Switch
Cable (Ref)
Box Mounting
Tab
Foot Switch
Hood
Switch
Relay
Receptacle
Stop
Switch
Power
Cord
Black
Black
Black
Black
Black
White
White
White
Green
Green Screw
Supplied with
Round Box
Ground Lug Detail
04" Round Outlet Box
Green Wire
White
White
Black