Port modes, Gsm basic parameters – 2N VoiceBlue MAX v1.2 User Manual
Page 47

47
Port Modes
This item helps you set each of your gateway ports. The settings are based on
the LCR table including relevant routing/rejecting rules for all incoming and
outgoing calls.
GSM basic parameters
Count of digits dialled from VoIP
Minimum digits from VoIP – minimum count of digits to be dialled into GSM.
Maximum digits from VoIP – maximum count of digits to be dialled into GSM.
Wait for next digit [s] – timeout during which
awaits
2N VoiceBlue
®
MAX
further digits dialled from VoIP to GSM.
Calls
Relax timeout [s] – time interval between the end of the last call and the
beginning of the next call via one and the same GSM module (all incoming and
outgoing calls are rejected during this timeout). The recommended value is 2
seconds. Do not change this setting unless absolutely necessary.
Timeout for ringing to GSM [s]
– ringing timeout for outgoing calls to GSM. If not
answered or terminated within this timeout, the call will be terminated
automatically by the gateway when this timeout elapses.
Bank holiday list
A list of dates to which the weekend routing mode should be applied in the LCR table.
DTMF settings
The minimum delay between two identical DTMF characters received [s/100].
Tone detector settings
The GSM gateway can automatically detect user defined tones sent by the GSM/UMTS
network during call setup. In general, user defined tones are tones of the number to be
transmitted. Having detected such tone, the GSM gateway terminates the call
automatically and attempts to set it up through the next available outgoing group (as
defined in the LCR table).
Frequency 1;2;3;4 – defined frequency of the tone to be detected.
Sequence list – sequence of the above defined tones for detection.
Voice message detector settings
Minimum percent to match – set the match percentage range in which the voice
message is detected as identical with one of the voice messages recorded in the
section under index 30 - 37. The
Gateway control–>Voice messages
recommended value is 70-90%.