System Settings
AT%S70=x.x.x.x – IP address
AT%S71=x.x.x.x – IP address mask
AT%S81= – Initialisation string for setting of mode connected to the gateway
COM2
AT%S90=x –
Type of assignment of B-channels to GSM modules and X
0 – rotating
1 – locked
2 – according to credit
AT%S91=x,y –
Way of call information recording
X:
0 – no record
1 – successfully connected outgoing call
2 – successfully connected incoming calls
3 – successfully connected incoming and outgoing calls
5 – all outgoing calls
6 – all incoming calls
7 – all incoming+outgoing calls
Y – to each call add NET info (1) or no (0)
AT%S93=x – Global selection of SIM card and X:
0 – according to GSM group
1-8 – number of SIM holder
AT%S98=xxxx – PIN code for SIM cards inserted in the gateway
AT%S99= dd.mm.yy.w/hh:mm:ss – Gateway date and time settings
AT%X00=hout,hin,min – Automatic logout of GSM modules
hout – hour when the modules start to log out randomly
hin – hour when the modules start to log in randomly
min – minimum number of modules in a group (2..15) that always remain
logged-in
AT%X80=name/pass –
Username/password for access via IP port (this
parameter is write only – you cannot see its value)
System Control
AT&BSYS=RESET –
Reset of PRIGW
AT&Gxx=RESET –
Reset of GSM module xx
AT&Gxx=BLOCK –
Block of GSM module xx
AT&Gxx=DOWN –
Transfer of GSM module into the sleep mode
AT&Gxx=ON –
Transfer of GSM module into the idle mode