2N Omega Lite - Configuration Tool manual v1.8 User Manual
Page 56
![background image](/manuals/553553/56/background.png)
56
Block Out
– only an incoming external line and it cannot be entered on in the
outgoing direction
Auto TEI
Without authorisation
– checks on authorisation not made on this line
Private
– a line connected to a private network to which charging is not done
Receive overlap dialling
– only for special PTMP applications
Send CLIP
– it is possible to forward the caller‟s CLIP to a private ISDN line.
Synchronising PBX time
– during an outgoing call the PBX time is
synchronised with the ISDN operator‟s time (if the operator provides this)
Fax line
– labelling an ISDN fax line. Calling is with 3.1 audio signalling.
Prefix- a 4-digit prefix, which is automatically chosen as the first (DID through a
superior PBX) after engaging a line. The prefix is not recorded in the charging
row.
Min. time for accounting
– the period deducted from the call time for
temporary charging
Priority
– an internal line must have higher or the same priority so that it can
use this external line.
Series
1-8
– fill in the series number or numbers (incoming series number without
DID numbers or leave the series empty
– if the ISDN network operator only
sends a DID number, for precise information ask the operator of the ISDN
network)
MSN
– the line in the PTMP connection
MSN
1-8
– fill in the MSN number 1 to 8
Main group
– dividing up the MSN numbers into two groups for the option of
switching to the DAY/NIGHT regime and other functions related to group 1 / 2.
Deactivating 2
nd
layer
– by authorising it deactivates the second ISDN layer
after setting the time.