21
-2
nd
Frequency = Amplitude to 31
-3
rd
Frequency = Amplitude to 21
Generator 1 (sine 1)
-Default frequency 425 Hz.
Generator 2 (sine 2)
-
Example of forming a “British tone”.
Amplitude of the voice modules
The default value is set at 64 and it is not recommended to change it.
Busy tone detector parameters
Count of CPT periods
-minimum count of tones (beeps) according to
ITU-T E.180 before hang-up;
Silence fluctuation
-intensity of the silence signal (0-65535).
Jitter period
-tone duration tolerance against silence, starting from
tone:silence = 1:1 [ms];
CPT detection threshold behind filter
-minimum tone level (0-255) for the tone to
be considered present.
2.1.7. Parameters for voicemail
Voicemail
a line (or department) to which the modem of a voice
system is connected, Audio lines (Kerio VoiceMail) and the
ITS voice system lines.
Identification of mailbox
selection prefix before the identification sign (the
default setting is a pause of 1s).
DTMF for call clear return from being put through (called subscriber is
engaged)
Increasing of DTMF resistant for VMail. Min. length of the DTMF sign that is
accepted in VoiceMail.
Use protocol ITS
permission/prohibition for the voice mail ITS
Use protocol 602
permission/prohibition for the voice mail SW602
2.1.8. Authorisation numbers
Tables A, B, C, D, E, F for programming authorisations. Tables A, B, C, D
are prohibitive and conversely tables E and F are for exemptions and have greater
priority. Every table has 16 rows. Local numbers up to 5 digits can be entered into
tables A and B, the rest take ten digits.
Apart from the numbers it is also possible to add the sign “?”, which presents
all numbers (0-9).