The items listed in the service and maintenance schedule are to be checked, and if necessary, corrective action taken. This schedule

is designed for units operating under normal conditions. If the unit is operating in adverse or severe usage conditions it may be

necessary for the items to be checked and serviced more frequently.
See engine owners manual for further maintenance and troubleshooting information.

SERVICE AND MAINTENANCE SCHEDULE

FREQUENCY

COMPONENT

MAINTENANCE

REQUIRED

BEFORE

EACH USE

EVERY

8

HRS

EVERY

25

HRS

EVERY

50

HRS

EVERY

100 HRS

EVERY

200 HRS

EVERY

500 HRS

EVERY

1500 HRS

NUTS & BOLTS

CHECK TORQUE

CHIPPER BLADES

CHECK, SHARPEN

IF NEEDED

1

ENTIRE MACHINE

CLEAN

ROTOR BEARING

GREASE

BELTS

CHECK

1

It is a good sign that your chipper blades need sharpening when material stops self feeding.

Service & Maintenance

5.1 MAINTENANCE SCHEDULE

5.2 DISK LOCK

Follow the steps below to install the disklock:

Remove the plastic rotor shaft cover under the chipper chute.

There is a hole in the rotor jack shaft and a matching hole in

the bracket mounted to the rotor bearing frontside.
Install a punch or screwdriver into the rotor shaft and bracket

to lock the disk in place.

1.

2.

DISK ASSEMBLY

DISK LOCK HOLE

ROTOR SHAFT COVER

MATCHING HOLE

Figure 5.1 - Disk Lock

The disk assembly has a lock mechanism. When working on

the disk assembly, use the lock mechanism at all times.