Second half of clamp. zerk, 4 chute extension tray (optional), 5 discharge tube – Echo 76824 Owners Manual v.1 User Manual
Page 12
PN 18280-00 R121505
10
ASSEMBLY
2.4 CHUTE EXTENSION TRAY (OPTIONAL)
The Optional Chute Extension Tray is purchased sepa-
rately.
After mounting the chute to the hydraulic feed, slide the chute
extension tray over the chipper chute as shown in Figure
2.2.
Make sure that you position the lip on the extension
tray behind the lip on the chipper chute. Align the five
bolt holes in the chute extension tray with the bolt holes in
the extension hinge.
Insert a 3/8" x 1" carriage bolt (included in owner's kit) through
the two outside holes on the extension tray and the extension
hinge. Secure the bolts with washers and nuts.
Insert one 3/8" x 1" carriage bolt through the end of the chute
support and middle holes on the extension hinge and exten-
sion tray. Secure the bolts with washer and nuts. Secure
with hairpin clips.
1.
2.
3.
Figure 2.2 - Chipper Chute Extension Tray Assembly
Hairpin Clip
Feed Control
Lever
C h i p p e r
Chute
E x t e n s i o n
Hinge
E x t e n s i o n
Tray
Position this lip
behind the lip
on the chipper
c h u t e s h o w n
below. Hold the
extension tray
directly above
t h e c h i p p e r
chute and slide
it downward.
2.5 DISCHARGE TUBE
Attach the discharge tube to the mounting flange on the chip-
per frame. Half of the mounting clamp is already attached
to the tube. Slide the tube onto the flange and tighten the
bolts to secure it.
Install the second half of the clamp to the tube and flange.
Grease the zerk and tighten the nuts completely.
Loosen each nut one turn and attempt to rotate the tube.
If it does not rotate freely, loosen each nut 1/2 turn until it
rotates freely.
Rotate the tube 360 degrees and lock it in place with the
handle to make sure it is mounted correctly.
1.
2.
3.
4.
5.
Figure 2.4 - Control Cable Assembly
Keep nuts as tight as possible while allowing the discharge
tube to freely turn.
NOTE
SECOND HALF
OF CLAMP.
ZERK