SERVICE & MAINTENANCE

BEFORE INSPECTING OR SERvICING ANY PART OF ThIS MAChINE, ShuT OFF POWER SOuRCE,

DISENGAGE ThE hYDRAuLICS, OPEN ShIELD AND MAkE SuRE ALL MOvING PARTS hAvE COME TO A COMPLETE STOP.

WARNINg

5.9.3 hYDRAuLIc puMp sTART up

Follow this start-up procedure when starting a new installation

or when restarting an installation in which the hydraulic pump

has been removed from the system.

Before starting the hydraulic pump, make sure all system

components (reservoir, fittings, etc.) are clean.
Add recommended hydraulic fluid to the reservoir. The hy-

draulic fluid should be filtered before it enters the reservoir.
Run the unit and move the control bar in both directions for

several minutes until all air is purged from the unit. Refill the

reservoir as necessary.
Shut down the engine, check for and correct any fluid leaks,

and check the reservoir level. Add fluid if necessary. The

hydraulic pump is now ready for operation.

1.

2.

3.

4.

5.9.1 hYDRAuLIc fLuID

The machine is tested before shipping. In order to test the ma-

chine, the fluid levels are filled. However, before starting the ma-
chine, check the hydraulic fluid level in the reserve tank.

Premium hydraulic fluids containing high quality rust, oxidation,

and foam inhibitors are required. These include premium turbine

oils, API CD engine oils per SAE j183, M2C33F or G automatic

transmission fluids meeting Allison C-3 or Caterpillar TO-2, and

certain specialty agricultural tractor fluids.

5.9 hYDRAuLIcs

5.9.2 hYDRAuLIc fEED MAINTENANcE

The hydraulic pump normally does not require regular fluid

changes. The system filter should be changed after 250 hours

of operation or annual intervals. The fluid and filter should be

changed and system cleaned if the fluid becomes contaminated

with foreign matter (water, dirt, grease, etc.) or if the fluid has

been subjected to temperature levels greater than the maxi-

mum recommended.
There is a greaseable bearing on each side of the main jack

shaft on the main hydraulic feed housing. Grease according to

the Maintenance Schedule in Section 5.1.

Before servicing or repairing any of the hydraulic feed com-

ponents (pump, motor, and/or relief valve), contact your

dealer or factory service department. Warranty on these

items may be void without prior authorization.

WARNINg

Handle pressurized hydraulic fluid carefully. Escaping pres-

surized hydraulic fluid may penetrate your skin causing seri-

ous injury. This fluid may also be hot enough to burn. Serious

infection or reactions can develop if immediate proper medi-

cal treatment is not administered.

WARNINg

hydraulic pressure controlled by the relief valve is factory

set at 2500 PSI.

NoTE

5.9.4 hYDRAuLIc oIL fILTER

using an oil filter wrench, turn the filter counterclockwise.
Once the filter becomes loose, turn it out the rest of the way

with your hand.
Properly discard old filter.
Lube the rubber seal on the new filter with clean hydraulic

oil.
Install the filter onto the threaded pipe. Turn by hand until

the filter is finger tight.
using an oil filter wrench, tighten the filter another 1/2 turn.
Check hydraulic oil level and fill if necessary.

1.
2.

3.
4.

5.

6.
7.