PTO CHIPPERS

21

TROUBLESHOOTING

PrOBleM

PrOBaBle cauSe

SuggeSTed SOluTiONS

Will not attain normal

feed rate

engine not operating at correct speed. repair engine governor.

control linkage damaged or binding.

repair control linkage.

Bypass valve stuck partially open (Prob-

lem in one direction only).

repair bypass valve.

remove foreign material from valve.

Will not feed when

control arm is moved.

control linkage damaged or not

connected.

repair or reconnect control linkage.

drive between engine and pump

damaged.

repair drive (replace broken belt,

repair sheared key, repair spined

coupling, etc.)

Pump low on fluid.

Refill reservoir. Purge air from

transmission.

feed rate is sluggish

under load.

loose drive belt between engine and

pump.

Tension drive belt (replace if necessary).

Pump low on fluid.

Refill reservoir. Purge air from

transmission if necessary.

Large amount of water in hydraulic fluid

(evaporates when hot, resulting in low

fluid level).

Drain fluid from reservoir and unit, re-

place filter element, and refill with new

fluid.

hydraulic feed will not

pull in logs over 9" in

diameter.

hydraulic system overloading.

check relief pressure in system with a

pressure gauge rated to 2500 psi (sys-

tem set by factory at 1750 psi).