SECTION 1 - SPECIFICATIONS

1-22

– JLG Lift –

3120858

Figure 1-9. Torque Chart (METRIC Fasteners - Sheet 2 of 3)

Size

PITCH

Tensile

Stress

Area

Clamp

Load

Torque

(Dry or Loctite®

263

TM

)

K = 0.20

Torque

(Lub OR Loctite®

242

TM

or 271

TM

OR

Vibra-TITE

TM

111 or

140)

K= 0.18

Torque

(Loctite® 262

TM

OR

Vibra-TITE

TM

131)

K=0.15

Sq mm

KN

[N.m]

[N.m]

[N.m]

3

0.5

5.03

3.13

3.5

0.6

6.78

4.22

4

0.7

8.78

5.47

5

0.8

14.20

8.85

6

1

20.10

12.5

7

1

28.90

18.0

25.2

22.7

18.9

8

1.25

36.60

22.8

36.5

32.8

27.4

10

1.5

58.00

36.1

70

65

55

12

1.75

84.30

52.5

125

115

95

14

2

115

71.6

200

180

150

16

2

157

97.8

315

280

235

18

2.5

192

119.5

430

385

325

20

2.5

245

152.5

610

550

460

22

2.5

303

189.0

830

750

625

24

3

353

222.0

1065

960

800

27

3

459

286.0

1545

1390

1160

30

3.5

561

349.5

2095

1885

1575

33

3.5

694

432.5

2855

2570

2140

36

4

817

509.0

3665

3300

2750

42

4.5

1120

698.0

5865

5275

4395

CLASS 10.9 METRIC BOLTS

CLASS 10 METRIC NUTS

CLASS 12.9 SOCKET HEAD CAP SCREWS M3 - M5*

4. CLAMP LOAD LISTED FOR SHCS IS SAME AS GRADE 8 OR CLASS 10.9 AND DOES NOT
REPRESENT FULL STRENGTH CAPABILITY OF SHCS. IF HIGHER LOAD IS REQUIRED,
ADDITIONAL TESTING IS REQUIRED.

*3. ASSEMBLY USES HARDENED WASHER OR FASTENER IS PLACED AGAINST PLATED
STEEL OR RAW ALUMINUM

NOTES: 1. THESE TORQUE VALUES DO NOT APPLY TO CADMIUM PLATED FASTENERS

2. ALL TORQUE VALUES ARE STATIC TORQUE MEASURED PER STANDARD AUDIT
METHODS TOLERANCE = ±10%

NO. 5000059 REV. J