JLG 800A_AJ Service Manual User Manual
Page 358
SECTION 6 - JLG CONTROL SYSTEM (S/N 0300065534 TO PRESENT)
6-26
– JLG Lift –
3120858
FUNCTION CUTOUT:
18*
* Only visible under certain
market selections.
* Certain market selections
will limit function cutout
options or alter default set-
ting.
0
1
2
3
NO: No drive cutout.
BOOM CUTOUT: Boom function cutout while driving above elevation.
DRIVE CUTOUT: Drive & steer cutout above elevation.
DRIVE CUT E&T: Drive & steer cutout above elevation and tilted.
0
GROUND ALARM:
19*
* Certain market selections
will alter default setting.
0
1
2
3
NO: No ground alarm installed.
DRIVE: Travel alarm sounds when the drive function is active (Option).
DESCENT: Descent alarm sounds when lift down is active (Option).
MOTION: Motion alarm sounds when any function is active (Option).
3
DRIVE:
20*
* Only visible under certain
model selections.
0
1
2
4WD: Four wheel drive.
2WD: Two wheel drive.
2WD W/ 2-SPEED: Two wheel drive with 2-speed valve.
0
TEMPERATURE:
21*
* Certain market selections
will alter default setting.
0
1
CELSIUS: Celsius unit selection.
FAHRENHEIT: Fahrenheit unit selection.
1
LEVELING MODE:
22*
* Only visible on 800S
models.
0
1
ALL FUNCTIONS: Platform level with all functions.
LEVEL LIFT/TELESCOPE: Platform level on lift and telescope only.
0
4150364-18
Table 6-3. Machine Configuration Programming Information Software Version P5.3 to P6.1
Configuration Label/
Digit
Number
Description
Default
Number