JLG X500AJ Operator Manual User Manual
Page 46
![background image](/manuals/552281/46/background.png)
SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION
3-12
– JLG Lift –
3121636
Position 5
Displays that the outriggers are properly set
and boom functions are allowed. No dis-
play indicates that the outriggers are not
properly set and boom functions are not
allowed.
If an overload occurs the main screen goes
blank for 3 seconds followed by the over-
load error display and an alarm.
Position 6
Indicates that boom, jib, turntable and base
are aligned. Drive, steer, track width adjust-
ment and outrigger functions are opera-
tional if this symbol below is present. No
symbol indicates these functions are not
operational. Drive and steer are operational
if all 4 outriggers are not contacting the
ground.
1 2
3 4
5 6
7 8
1 2
3 4
5 6
7 8
Position 7
Can indicate any of the following situations:
• An emergency stop is pushed in (off ).
• A low battery. The batteries need
charged by running the gas engine or
connecting to a power source.
• CANBUS communication is faulty.
• Electronic fault.
• Lithium ION - Signals an error in the
BMS - Battery Management System
Position 8
• Indicates that emergency lowering has
been selected.
• Lithium ION - Battery Charge Status
• Lithium ION - Battery Charger Plugged
In.
1 2
3 4
5 6
7 8
CAN
BUS
?
CARD
?
1 2
3 4
5 6
7 8