Battery maintenance and charging - gas/ac-electric – JLG X500AJ Operator Manual User Manual
Page 126
SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
6-16
– JLG Lift –
3121636
Battery Maintenance and Charging - Gas/AC-Electric
NOTE:
The battery is a maintenance free battery. Do NOT
attempt to open a maintenance-free sealed battery.
External Battery Charger Use
WHEN AN EXTERNAL BATTERY CHARGER IS TO BE USED, CHARGING HAR-
NESS MUST BE PLUGGED INTO A GROUNDED RECEPTACLE. IF RECEPTA-
CLE IS NOT GROUNDED AND A MALFUNCTION SHOULD OCCUR, THE
MACHINE COULD CAUSE SERIOUS ELECTRICAL SHOCK.
1. Open battery cover.
2. Disconnect the terminal clamps from the battery
poles.
3. Connect the cables of the charger to the battery
poles. and turn on the battery charger
NOTE:
Re-charge voltage should never exceed 14.7 volts and
the load intensity shall be 0.2% of the value indicated
below and on the lid of the battery.
4. When charging is completed turn off the battery
charger before disconnecting the cables from the
battery poles
5. Return the terminal clamps to the battery poles
and lubricate with the appropriate product
6. Close battery cover.
IT IS GOOD PRACTICE TO AVOID PRESSURE-WASHING ELECTRICAL/ELEC-
TRONIC COMPONENTS. IN THE EVENT PRESSURE-WASHING THE
MACHINE IS NEEDED, ENSURE THE MACHINE IS SHUT DOWN BEFORE
PRESSURE-WASHING. SHOULD PRESSURE WASHING BE UTILIZED TO
WASH AREAS CONTAINING ELECTRICAL/ELECTRONIC COMPONENTS, JLG
INDUSTRIES, INC. RECOMMENDS A MAXIMUM PRESSURE OF 750 PSI (52
BAR) AT A MINIMUM DISTANCE OF 12 INCHES (30.5 CM) AWAY FROM
THESE COMPONENTS. IF ELECTRICAL/ELECTRONIC COMPONENTS ARE
SPRAYED, SPRAYING MUST NOT BE DIRECT AND BE FOR BRIEF TIME
PERIODS TO AVOID HEAVY SATURATION.