SECTION 5 - EMERGENCY PROCEDURES
5-18
– JLG Lift –
3121636
Start Procedure;
In the event of electrolyte release from the cells, proceed as
follows:
1. Evacuate the people exposed to fumes from the area.
2. Air the environment until the complete removal of the
cell and until the characteristic pungent odour has dis-
appeared.
3. If the cell is too hot, allow it to cool to ambient temper-
ature before handling it (see “Procedure For Handling
Hot Cells” on page 16).
4. Wear safety equipment: coat, gloves, mask and filters,
and move the cell to a well-ventilated area.
5. Place every cell in a sealable plastic bag and remove
the excess air, then seal the bag.
6. Place a cup of vermiculite in a second bag, place the
first bag in the second and seal it.
7. Place everything in a third bag with some baking soda
and seal the bag.
8. Absorb and collect the leaked electrolyte with absor-
bent material or baking soda.
9. Place the absorbent material in a bag and seal it.
10. Clean the area with plenty of water.
11. Dispose of the hazardous material in accordance with
the local legislation in force.
First Aid In The Event Of Contact With The Electrolyte
EYES
Immediately wash the eyes in abundant running water for
at least 15 minutes, keeping the eyelids open and flushing
the eye and back of the eyelid. Immediately seek medical
help.
SKIN
Wash in cold water under a shower, remove contaminated
garments. Continue washing for at least 15 minutes. Seek
medical help where necessary.
RESPIRATORY TRACT
Move the person(s) outdoors into the open air. If the per-
son(s) has difficulty breathing, have oxygen administered
by trained personnel. If breathing stops, apply mouth-to-
mouth resuscitation and immediately seek emergency
medical help.