SECTION 1 - SAFETY PRECAUTIONS

1-6

– JLG Lift –

3121211

Warn personnel not to work, stand, or walk under a raised

platform. Position barricades on floor, if necessary.

Be sure all safety devices are operating properly. Modifica-

tion of these devices is a safety violation.

Never operate machine in high wind, rain or snow.

Do not operate or raise the platform while on trucks, trail-

ers, railway cars, floating vessels, scaffolds or other equip-
ment unless approved by JLG.

Approved head gear must be worn by all operating and

ground personnel.

Read, understand, and obey all dangers, warnings, cautions

and operating instructions on the machine and in this man-
ual.

All operating personnel must be familiar with emergency

controls and emergency operation of the machine as speci-
fied in this manual.

Electrocution Hazard

Table 1-1. Minimum Approach Distance (M.A.D.)

VOLTAGE RANGE

(PHASE TO PHASE)

MINIMUM APPROACH

DISTANCE - Feet (m)

0-50KV

10 (3)

Over 50KV to 200KV

15 (5)

Over 200KV to 350KV

20 (6)

Over 350KV to 500KV

25 (8)

Over 500KV to 750KV

35 (11)

Over 750KV to 1000KV

45 (14)

NOTE: This Minimum Approach Distance shall apply except where

employer, local, or governmental regulations are more stringent.