The operator seat (1) is equipped with an operator presence system. Engine start
and hydraulic functions are prohibited if operator is not present. If the system detects
a loss of pressure during operation, after a two second delay one of the following will
occur:
1. With the park brake (2) engaged and transmission in neutral (3):
• Hydraulic controls are disabled. (Continuous Auxiliary function permitted)
• Upon returning to seated position, hydraulic controls are enabled.
2. With the park brake (2) disengaged and transmission in neutral (3):
• Hydraulic controls are disabled and horn sounds continuously. (Continuous
Auxiliary function permitted)
• Upon returning to seated position, hydraulic controls are enabled and horn
will cease.
3. With the park brake (2) disengaged and transmission in forward or reverse (3):
• Hydraulic controls are disabled, horn sounds continuously and transmission
shifts to neutral.
• Upon returning to seated position, hydraulic controls are enabled and horn
will cease. Return transmission to neutral to allow system to reset prior to
reengaging forward or reverse travel.
OZ4330
2
3
1
3
(IF EQUIPPED)