Symptom

Possible Cause

Corrective Action

Engine light in emergency stop

button is illuminated and engine

shuts off.

High engine temperature.

Let the engine cool. Do not restart

the engine until the cause of over-

heating has been corrected.

Low oil pressure.

Do not restart the engine until the

cause of low oil pressure has been

corrected. The engine can be re-

started with low oil pressure, but it

will only run a few seconds before

it shuts off again.

All functions stop working.

Low fluid level in reservoir.

Check fluid level. Add correct type

of fluid if necessary.

Engine or pump failure.

Manually stow the machine using

the emergency power system or the

emergency lowering knob.

Circuit breaker is tripped.

Push circuit breaker button in to

reset.

Electrical system malfunction.

Manually lower the boom using the

emergency lowering knob.

Lower controls do

not work.

Battery disconnect switch turned

off.

Place switch in the on position.

Emergency stop button at lower

controls is pushed in to the off posi-

tion.

Pull the emergency stop button

outward.

Controls selector switch is in the

platform position.

Place the switch in the ground

position.

Ground operation switch not held in

the on position.

Hold the ground operation switch in

the on position while operating the

control toggle switches.

Upper controls do not work.

Battery disconnect switch turned

off.

Place switch in the on position.

Emergency stop button at lower and

upper controls is in the off position.

Pull the emergency stop buttons

outward.

Control selector switch at lower

controls is in the lower controls

position.

Place switch in the upper controls

position.

Platform foot switch not engaged.

Step down on platform foot switch

while operating controls.

Boom will not extend or raise above

horizontal.

Rear axles not properly extended.

Extend the rear axles and properly

install the pin lock.

Boom and drive functions seem

sluggish.

Hydraulic oil is cold and thick.

Use cold weather hydraulic oil as

recommended for weather condi-

tions. Warm oil before operating

the machine.

Boom jerks while it is extended.

Wire ropes are loose.

Refer the problem to a qualified

service technician.

Booms drift down.

The emergency lowering valve is

open.

Turn the emergency lowering knob

to close the valve.

Hydraulic system malfunction.

Stow the machine and do not oper-

ate until repairs are made.