Chapter 7 – Prestart Inspection

34

T125J/TB125J – 0192214

Emergency Power

Place the battery disconnect switch, the emergency stop

button, and the master switch in the on position.

Hold the engine/emergency power switch down and the

ground operation switch upward to operate the aerial

platform from the lower controls using the emergency

power system.

Envelope Management System

Inspect and test the EMS sensors for wear, physical

damage and proper operation (refer to Figure 7.15).

Figure 7.15 – EMS Sensors

Use the following procedure to test and inspect the

EMS.

1. Turn on the ignition and start the engine.

2. From the lower controls, fully extend the boom hori-

zontally. The black and yellow striped tape should

be within 2 to 3′′ (5 to 8 cm) of being flush with the

hose carrier cover. (Refer to Figure 7.16) If more

or less tape is showing, remove the machine from

service and contact a Snorkel authorized service

provider.

Figure 7.14 – Lower Controls

Operating Controls

Use the following procedure to operate the machine

from the lower controls.

1. Turn the battery disconnect switch on.

2. At the lower controls, pull the emergency stop but-

ton outward. Place the control selector switch in the

lower control position.

3. Turn the key switch until the engine starts, then

release.

4. Let the engine warm to operating temperature.

5. Hold the ground operation switch upward.

Danger

Pinch points may exist between moving compo-

nents. Death or serious injury can result from

becoming trapped between components, build-

ings, structures, or other obstacles. Make sure all

personnel stand clear of the aerial platform while

performing the prestart inspection.

6. Test the operation of each function in both direc-

tions.

Note

When checking the turntable rotation function in the

clockwise direction, the turntable will rotate toward

you.

Emergency Stop

Push the emergency stop button in to turn off the engine.

The lower control functions should not operate with the

emergency stop in this position.

EMS Length

Sensors

Length Sensor

Cables

EMS Angle Sensor

Connector

EMS Angle

Sensors

Primary

Secondary

Primary

Secondary

Boom Speed Switch

Ground

Operation

Emergency

Stop

Engine/

Emergency

Power

Start

Controls

Selector