beautypg.com

Operating site, Noise and vibration, Limitations – Snorkel POP UP EC08 User Manual

Page 8

background image

Section 2

SPECIFICATION

Page 7 of 25

Operating site

Select a site for the machine from which the platform will be able to reach the

required work area. A visual inspection of the operating site should be made

before setting up the machine. Particular attention should be given to the

following items:

1. Ground conditions

Ensure that the ground on which the

Pop-Up+ is to operate is capable of

supporting the weight of the machine (including the weight of the operator plus

tools and materials). Be aware of floors or coverings (e.g. manhole covers) that

may not withstand point loadings exerted by the castor wheels.

and legs are fully deployed before the work platform can be raised. It is essential

that each of the four stabiliser feet are located on firm, solid ground. The

Pop-Up+

auto brake kit enables the removal of stabilisers for use in 0m/sec wind conditions.

2. Ground flatness

The

Pop-Up+ must only be operated on flat (0º chassis inclination) and level

surfaces. The allowable chassis inclination is indicated when the spirit level

bubble is within the marked limits. All castor wheels must be in full contact with

the ground.

Noise and vibration

Noise levels emitted from this machine do not exceed 70 dB(A). Hand and

arm vibration experienced on this machine does not exceed 0.5 m/s

2

.

Limitations

The

Pop-Up+ is limited to operation indoors. The machine must not be used

outdoors. Please consult the manufacturer if you are unsure of any application

for which the machine is to be used.
This machine has been tested for Electromagnetic Compatibility (EMC)

however, operation near to high powered radio transmission apparatus

(e.g. radar, antennae) or within strong electrical and/or magnetic fields may

affect some features of this product

WARNING

THIS MACHINE HAS NOT BEEN DESIGNED FOR OPERATION WITHIN

POTENTIALLY EXPLOSIVE ATMOSPHERES

WARNING

THIS MACHINE IS NOT ELECTRICALLY INSULATED AND MUST NEVER

BE USED FOR LIVE LINE WORKING. DEATH OR SERIOUS INJURY CAN

RESULT FROM CONTACT WITH, OR INADEQUATE CLEARANCE FROM,

ELECTRICAL CONDUCTORS

Operator’s Safety and Maintenance Handbook (

In indoor exposed areas with wind speeds up to 12.5m/sec the

Pop-Up+ can be

used with a stabiliser pack. An interlock system ensures that the stabiliser beams

3. Obstructions

When manoeuvring, raising and lowering, ensure that there are no obstructions

or persons that may be struck by the platform.

Pop-Up+

dual use machine rev.0.0.1.0210)

0120723