beautypg.com

Hydraulic oil – Snorkel POP UP EC08 User Manual

Page 18

background image

Hydraulic oil

The hydraulic oil level can be checked by removing the filler cap. The correct amount

of oil is in the tank when the tip of the level rod has hydraulic oil on it. This check must

be carried out on a level surface.
The hydraulic oil can be topped up by adding oil to the filler as shown below. Take

care not to spill hydraulic fluid over any of the surrounding machine components.
The hydraulic oil can be drained by removing the tank. Remove the bolts as shown

above and separate the tank from the pump body. The hydraulic fluid can then be

correctly disposed of.
Reassembly is the reverse of above.

Section 5

MAINTENANCE

Page 17 of 25

The hydraulic oil recommended for use with this

Pop-Up+ is:

mineral basis hydraulic oil with lubricating, antifoaming, anti-corrosive,

antioxidant HL-HLP (ISO and UNI HM)-HV-HLPD performances

according to DIN51524 part 1-2 standards

Minimum viscosity
Max. viscosity at starting up
Max. working viscosity
Suggested viscosity range
Allowed temperature
Recommended temperature

15cts (23

o

E / 77, 39 SSU at 100

o

F)

800cts (105,6

o

E / 3708 SSU at 100

o

F)

100cts (13,2 E / 463,5 SSU at 100

o

F)

25 ÷ 40 cts = (3,47 ÷ 5,35

o

E / 119,3 ÷ 186,3 SSU a 100

o

F)

Max 80

o

C (176

o

F)

30 ÷ 60

o

C (86 ÷ 140

o

F)

Bolts

Filler cap

Operator’s Safety and Maintenance Handbook (

Pop-Up+

dual use machine rev.0.0.1.0210)

0120723