beautypg.com

Platform control switches 7-7, Ac outlet rcd/elcb (option) 7-7, Ac outlet rcd/elcb, 7-7 – Snorkel MHP15J User Manual

Page 43: Caution

background image

Platform Control Switches

Figure 7.22 - Platform Control Switches

On the ground con trol box set the Ground/Plat -
form Se lec tor
to plat form.

Check that each of the platform moving switches
( through to ƒ) cause the platform to move the
way it should.

Check both po si tions of each switch.

For cor rect op er at ing pro ce dures see the ”Op er a -
tion” chap ter 8.

NOTE

Pay particular attention to the Emergency Stop
switch
„to see that it turns the MHP15J engine
off when struck.

Pay particular attention to the platform foot switch
to see that it deactivates the platform moving
switches when the foot switch is not stepped on.

AC Outlet RCD/ELCB (option)

Figure 7.23 - AC Outlet RCD/ELCB

If the MHP15J has this option fitted check the RCD
works by connecting a power source to the base
inlet and an appliance to the platform outlet.

Push the test but ton on the RCD/ELCB de vice and
the power out let at the plat form should not work.

RCD/ELCB devices should only be replaced
by a qualified electrician.

MHP15J – 11995A

page 7 - 7

7. Pre-operational Inspection

CAUTION