XRT Work Platform

B

ATTERY

M

AINTENANCE

Figure 10: Access to Battery

The battery is located in the slide out tray. The slide out tray is located at the rear of the machine.

• Reach through the ladder to pull the Release Latch, then pull the tray outwards.
• Check battery fluid level, if electrolyte level is lower than 3/8 in. (10 mm) above plates add

distilled water only. DO NOT use tap water with high mineral content, as it will shorten battery
life.

• The battery and cables should be inspected regularly for signs of cracks in the case, electro-

lyte leakage and corrosion of the terminals. Inspect cables for worn spots or breaks in the
insulation and for broken cable terminals. Keep terminals and tops of batteries clean.

• Refer to the Service Manual to extend battery life and for complete service instructions.

W A R N I N G

!

!

Hazard of explosive gas mixture. Keep sparks, flame, and smoking material
away from battery.
Always wear safety glasses when working near battery.
Battery posts, terminals and related accessories contain lead and lead
compounds, chemicals known to the State of California to cause cancer and
reproductive harm. Wash hands after handling.
Battery fluid is highly corrosive. Thoroughly rinse away any spilled fluid with
clean water.
Always replace battery with an UpRight battery or manufacturer approved
replacement.