8. EMERGENCY OPERATION
8 - 2
P/N 569300
2. Check to be sure the EMERGENCY STOP
switch (6) is on (up).
3. Check to be sure the MAIN POWER switch (7)
is on.
4. Check to be sure the SELECTOR switch (8) is
set to platform (up).
5. If the BATTERY (5), EMERGENCY STOP (6),
MAIN POWER (7), and SELECTOR switch (8)
are all set correctly, and the engine will not start
from the platform-control box, set the
SELECTOR switch (8) to base (down) and try to
lower the platform from the base-control panel.
D A N G ER
PINCHING AND CRUSHING HAZARD. At the
next step the platform will come down and
the scissor arms will close. Keep all body
parts out of the scissor arms and out from
under the platform.
6. If the platform will not lower, the person on the
ground should reach through the opening
immediately below the base-control panel and
screw open the emergency bleed-down valve (9)
until the platform begins to slowly descend.
NOTE: If you need to stop decent, screw the
emergency bleed-down valve (9) back in.
NOTE: As soon as the platform is completely
down, close the emergency bleed-down valve
(9).
NOTE: If the platform does not come down,
refer the problem to a qualified trained service
technician.
T
PUSHING
An SR can be safely pushed by hand on level
firm surfaces. To do so:
1. Turn the BATTERY switch (1) to OFF.