5.3 Hydraulic supply
The direction of the piston movement is determined via the control valve (cover sheet, item 1).
This is controlled via the distribution valve (cover sheet, item 2).
5.4 Control of the work movements
NOTE:
You should always contact LUKAS or an authorised dealer before using pumps
of other producers.
The Mobile Selection Manifold and pump unit are connected via hose lines.
There are already two short hose lines with a monocoupling connection or a quick-disconnect
coupling pair on the Mobile Selection Manifold. If the length of hose lines is not sufficient for
connecting to the pump units, then the connection can be extended by using LUKAS hose
5.5 Connection between Mobile Selection Manifold and motor
The hydraulic supply must be provided via a LUKAS hydraulic unit.
pump
The Mobile Selection Manifold and hydraulic cylinders are connected via hose lines.
They are not included within the scope of delivery of the Mobile Selection Manifold!
The hose lines are connected exclusively via quick-disconnect couplings.
Connection of the devices
6.
6.1 Hydraulic
Two short hose lines with a monocoupling or a quick-disconnect coupling pair are provided
on the device side; they are connected to the pump unit via a hose pair.
Two quick-disconnect male couplings and two quick-disconnect female couplings are
provided for the connection to the hydraulic cylinders. They are connected to hydraulic
cylinders via hoses / hose pairs. Each is equipped, respectively, with quick-disconnect male
coupling A1 and quick-disconnect female coupling B1 and quick-disconnect male coupling
A2 and quick-disconnect female coupling B2.
All hose lines are colour-coded in order to ensure a distinction between supply and return line.
In connection with the couplings installed on the added hose lines and on the hose line
extensions (accessories), a non-reversible connection to the device is ensured.
NOTE:
When controlling single-acting cylinders, the connection to ports B1 and B2 is
omitted.