If the defects cannot be remedied, notify an authorised LUKAS dealer or contact LUKAS

Customer Service directly!

The address of LUKAS customer service is:

LUKAS

Hydraulik GmbH

Weinstraße 39, D-91058 Erlangen

Postfach 2560, D-91013 Erlangen

Phone: (+49) 09131 / 698 - 348

Fax.: (+49) 09131 / 698 - 353

In the case of a

quick-disconnect

coupling system:

Hose lines cannot be

connected

Is the pump

running?

They are under

pressure

Relieve pump

pressure

Coupling defective

Coupling should be

replaced immediately

Hydraulic fluid

escaping from the

hoses or at the joints

Are the hose lines

defective?

Leakage, possible

damage

Replace hoses

Damage on the

surface of the

hydraulic hoses

Mechanical damage

or contact with

aggressive media

Replace hoses

Leakage at the

couplings

Coupling

damaged?

Coupling defective

Coupling should be

replaced immediately

Because all values are subject to tolerances, there may be small differences between the

data of your device and the data of the following tables!

Technical data

11.

* 1 MPa = 10 bar

Type

MSM-2D PN500-STREAM

Ref. No.

119006000

179006000

Dimensions

l x w x h

[mm]

330 x 180 x 270

[in.]

12.99 x 7.09 x 10.63

Weight

(including hydraulic fluid

filling)

[kg]

5,8

6,0

[lbs.]

12.8

13.2

max. operating pressure

(pump - mobile selection

manifold)

[MPa]*

70

[psi.]

10,153

max. operating pressure

(mobile selection manifold -

cylinder)

[MPa]*

50

[psi.]

7,252

Coupling system

(to the unit)

quick-disconnect

coupling

monocoupling