6.3 Connecting the quick-disconnect couplings
The hydraulic cylinders and the hydraulic unit are connected to the Mobile Selection Manifold
via quick-disconnect halves (female and male) in such a way that they cannot be mistakenly
reversed.
Before connecting the couplings, remove the dust cap, then pull back and hold the locking
sleeve of the female coupling (Position X). Push the male and female couplings together and
release the locking sleeve. Finally, turn the locking sleeve into Position Y. The connection is
then made and secured. Decoupling is done in the reverse sequence.
WARNING / CAUTION / ATTENTION!
The quick-disconnect couplings have special functions, in part, and therefore
must
not be unscrewed and/or reversed!
X
Y
The supplied dust caps must be reattached to protect against infiltration of dust.
NOTE:
Making the coupling connection is only possible if the hoses are
depressurised.
NOTE:
When controlling single-acting cylinders, omit the connection to the quick-
disconnect female couplings.
Operation
7.
7.1 Preparatory measures
WARNING / CAUTION!
Before the system components are installed, the vehicle to be raised / the load to
be raised needs to be properly secured against rolling and slipping away according
to the respective applicable national / international guidelines and regulations!