Lukas MSM-2D mobile control module User Manual
Page 17
17
ATTENTION!
Make sure that the "T" joint of the Mobile Selection Manifold is always connected
to the "T" joint of the monocoupling!
2. Loosen coupling nuts of the hose lines and remove coupling.
3. Set new coupling in place and tighten coupling nuts of the hose lines with a
torque of M
A
= 40 Nm and slide the cover of the couplings back on.
9.3.3 Quick-disconnect couplings
The quick-disconnect couplings should be replaced if:
- exterior damage is present,
- the lock does not function,
- in the coupled and/or decoupled state, hydraulic fluid continuously escapes.
WARNING / CAUTION / ATTENTION!
Couplings must not be repaired; they must be replaced with original LUKAS
parts!
During installation in the valve block, tighten the coupling with a torque of M
A
= 40 Nm.
Procedure:
1. Unscrew coupling from the Mobile Selection Manifold.
2. Fit new coupling and screw on with a torque of M
A
= 40 Nm.
ATTENTION!
The couplings need to be installed as illustrated on the cover sheet!