6 operating and storage temperature ranges, 7 oscillation / vibration – Lukas SC 357 E2 User Manual
Page 41

41
11.6 Operating and storage temperature ranges
Operating temperature
[°C] /
[°F]
-20 … +55
-4 …
+131
Ambient temperature
(device in operation)
[°C] /
[°F]
-25 … +45
-13 …
+113
Storage temperature
(device not in operation)
[°C] /
[°F]
-30 … +60
-22 …
+140
11.7 Oscillation / vibration
The total oscillation value / vibration value to which the upper limbs are exposed, is usually
below 2.5 m/s².
Higher values may be measured for short periods as a result of interaction with the materials
to be processed.
(The oscillations / vibrations were determined in accordance with DIN EN ISO 20643.)
11.8 Torques for central bolts (only for cutter and combination devices)
Device type
S 311 E2
S 700 E2
SC 250 E2 SC 357 E2
Pivot bolt
M 24 x 1.5 M 32 x 1.5
M 24 x 2
M 24 x 1.5
Wrench size
[mm]
36
46
36
36
[in.]
1.42
1.81
1.42
1.42
Torque
[Nm]
120 +10
140 + 10
110 +10
120 +10
[lbf
∙in]
1060 + 90
1240 + 90
890 + 90
1060 + 90