JB Conversions 16-1204 HD Standard Length SYE Kit for the NP241 User Manual
Page 14

14
FIG: 27
25) Install the 10mm bolts to hold the two case halves together.
26) Visually verify that the pump pickup tube is in place and has not
become disconnected from the pump housing.
27) Install the small retaining ring onto the second to lowest groove
on the shaft above the pump (Fig.28a). Install the blue speedometer
gear onto the mainshaft followed by the second snap ring onto the top
groove (threaded end).
FIG: 28a