beautypg.com

Vernier – Class1 Throttle Information Reference User Manual

Page 7

background image

7

e:\manuals\throttles\LDSBBT.p65

Turn

1

2

3

4

5

6

7

VDC

0.5

1.2

1.9

2.6

3.3

4

4.3

K-ohm

1.55

2.8

4.2

4.9

6.9

7.9

9.4

0.5

1.2

1.9

2.6

3.3

4

4.3

1.55

2.8

4.2

4.9

6.9

7.9

9.4

0

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

7

Turns

Va

lue

Voltage
Kilohms

THROTTLE SIGNAL

5 VDC

GROUND

Vernier Throttle

manuals\throttles\GENERIC.ai

Remote Throttle

Switch

OEM Interlocks

Remote Throttle

ON/OFF Switch

Generic Remote Throttle connections for analog voltage signal and remote turn on function.

Vernier

Vernier Throttle Voltage/Resistance relationship by full turns. Readings taken from the Black
wire (ground) to the Green wire (signal). Regulated 5 VDC is applied to the Red Wire for
Voltage readings. This chart can be used to troubleshoot throttles in the field using the ground
and 5 VDC supply from the engine ECM or Class1 Interface Module. Voltage readings pro-
vide more reliable information than resistance checks. Field readings should be within 5 % of
those shown.
Vernier 101558 readings will be slightly different since it uses a scaled voltage throttle.