Pressure gauge, Pump discharge – Class1 Digital Pressure Gauge User Manual
Page 4
![background image](/manuals/546732/4/background.png)
page 4 of 6 pages
Engineering
Standards
Name
Identifier
Instructions
Engineering Standard Number
C1-102190-A
Digital Pressure Gauge
PIN
COLOR
FUNCTION
A
BLACK
SENSOR GROUND
B
RED
SENSOR SUPPLY
C
WHITE
SENSOR SIGNAL
PIN COLOR
FUNCTION
1 PLUG
2 WHITE
SIGNAL
3 RED
SENSOR SUPPLY
4 RED
POWER IN
5 BLACK
GROUND IN
6 BLACK
SENSOR GROUND
7 PLUG
8 PLUG
Installation and Operation of the
Class1
Digital Pressure Gauge.
The pressure transducer (PN 102161) mounts to the pump with a 1/4” NPT fitting. Mount
the pressure transducer on the pump discharge manifold and tighten using the 1-1/4 hex.
Mount the digital display on the pump panel using the dimensions provided.
Connect the wiring harness PN 102035, 102060, or 102061 to the transducer, the display
and to the vehicle power and ground circuits.
Operation is straightforward.
When the unit is turned on, the display indicates pump pressure at the trans-
ducer location. Normally no calibration is required, however if the gauge
does not read zero when the pump is not running, a ZERO calibration can be
performed. Password L R R L L.
This feature is available only on rP1.7 and above.
Harness PN 102060 5’
102035 10’
102061 20’
Red +12 VDC
Black Ground
Pressure Gauge
PUMP DISCHARGE
1
2
3
4
8
7
6
5
Wire Insertion View