beautypg.com

Pressure gauge, Pump discharge – Class1 Digital Pressure Gauge User Manual

Page 4

background image

page 4 of 6 pages

Engineering
Standards

Name

Identifier

Instructions

Engineering Standard Number

C1-102190-A

Digital Pressure Gauge

PIN

COLOR

FUNCTION

A

BLACK

SENSOR GROUND

B

RED

SENSOR SUPPLY

C

WHITE

SENSOR SIGNAL

PIN COLOR

FUNCTION

1 PLUG
2 WHITE

SIGNAL

3 RED

SENSOR SUPPLY

4 RED

POWER IN

5 BLACK

GROUND IN

6 BLACK

SENSOR GROUND

7 PLUG
8 PLUG

Installation and Operation of the

Class1

Digital Pressure Gauge.

The pressure transducer (PN 102161) mounts to the pump with a 1/4” NPT fitting. Mount
the pressure transducer on the pump discharge manifold and tighten using the 1-1/4 hex.
Mount the digital display on the pump panel using the dimensions provided.

Connect the wiring harness PN 102035, 102060, or 102061 to the transducer, the display
and to the vehicle power and ground circuits.

Operation is straightforward.
When the unit is turned on, the display indicates pump pressure at the trans-
ducer location. Normally no calibration is required, however if the gauge
does not read zero when the pump is not running, a ZERO calibration can be
performed. Password L R R L L.
This feature is available only on rP1.7 and above.

Harness PN 102060 5’

102035 10’
102061 20’

Red +12 VDC

Black Ground

Pressure Gauge

PUMP DISCHARGE

1
2
3
4

8
7
6
5

Wire Insertion View