AEM 30-6320 Series 2 Plug & Play EMS User Manual
Page 9
![background image](/manuals/546687/9/background.png)
Page 9 of 13
Connection Diagram for EMS P/N 30-6320
PnP
Means the Plug and Play system comes with this configured for proper operation of this
device. Is still available for reassignment by the end user.
Avail
Means the function is not currently allocated and is available for use
Dedicated
Means the location is fixed and cant be changed
Pin
2006 Mitsubishi Lancer EVO IX
AEM EMS 30-6320
I/O
Notes
1
No. 1 Injector
P&H Injector #1
Output
Injector 1 (Peak/Hold 4A/1A
driver)
2
No. 4 Injector
P&H Injector #4
Output
Injector 4 (Peak/Hold 4A/1A
driver)
3
Front Heated Oxygen Sensor Heater
Low Side Driver #1
Output
Available Switched Gnd,
1.5A Max
4
---
PW #3
Output
Available Switched Gnd,
1.5A Max
5
Secondary Air Control Solenoid Valve (European EVO Only)
Idle #5
Output
Available Switched Gnd,
1.5A Max
6
EGR Vacuum Solenoid (US Only) / Wastegate Solenoid 2
(European EVO Only)
Injector #8
Output
Available Switched Gnd,
1.5A Max
7
---
---
---
---
8
Generator G Terminal
Injector #7
Output
PnP for Alternator Control
9
No. 2 Injector
P&H Injector #2
Output
Injector 2 (Peak/Hold 4A/1A
driver)
10
---
Injector #5
Output
Available Switched Gnd,
1.5A Max
11
Ignition Power Transistor Coil 1 & 4
Coil #1
Output
PnP for Coil 1 / Coil1B
12
Ignition Power Transistor Coil 2 & 3
Coil #2
Output
PnP for Coil 2 / Coil2B
13
---
CAN1H
---
Dedicated
14
Stepper Motor Coil A1
Idle #1
Output
PnP for Stepper Idle Motor
15
Stepper Motor Coil B1
Idle #3
Output
PnP for Stepper Idle Motor
16
Evaporative Emission Purge Solenoid
Idle #7
Output
Available Switched Gnd,
1.5A Max
17
---
Injector #11
Output
Available Switched Gnd,
1.5A Max
18
Fan Control Module
Low Side Driver #9
Output
User 1 PW output, coolant
19
Volume Airflow Sensor Reset Signal
Injector #9
Output
PnP for VAF Sensor
20
A/C Compressor Clutch Relay
Low Side Driver #6
Output
PnP for A/C
21
Fuel Pump Relay
Low Side Driver
#11
Output
PnP for Fuel Pump Control
22
Malfunction Indicator Lamp
Low Side Driver
#10
Output
Available Switched Gnd,
1.5A Max
23
---
High Side Driver #1
Output
Available Switched 12V, 1.5A
Max
24
No. 3 Injector
P&H Injector #3
Output
Injector 3 (Peak/Hold 4A/1A
driver)
25
---
Injector #6
Output
Available Switched Gnd,
1.5A Max
26
Rear Heated Oxygen Sensor Heater
Low Side Driver #2
Output
Available Switched Gnd,
1.5A Max
27
PW #1i
Output
Available Switched Gnd,
1.5A Max
28
Stepper Motor Coil A2
Idle #2
Output
PnP for Stepper Idle Motor
29
Stepper Motor Coil B2
Idle #4
Output
PnP for Stepper Idle Motor
30
Condenser Fan Relay HI
Low Side Driver #3
Output
PnP for Fan Control
31
Condenser Fan Relay LO
Low Side Driver #5
Output
PnP for Fan Control
32
Oil Feeder Control Valve
Injector #10
Output
PnP for MIVEC VVC
33
---
CAN1L
---
Dedicated
34
Sensor Ground
Sensor Ground
Output
Dedicated, sensors only
35
Evaporative Emission Ventilation Solenoid
Low Side Driver #8
Output
Available Switched Gnd,
1.5A Max