Page 22

Rich of Peak leaning is as simple as:

A. Pre-lean your mixture.
B. Tap the LF button (verify ROP appears).
C. Lean mixture until LEANEST flashes (peak found).
D. Enrichen to the desired value ‘Rich Of Peak’.

R

Procedure

Scanner Example

Comments

1

Establish cruise at 65
to 75% power.

2

Pre-lean the mixture
to 50°F estimated
rich of peak on any
EGT: _________°F.

EGT

1490

CHT

370

*

See ‘Pre-leaning’

3

Wait one minute

Let engine stabilize.

4

Tap the LF button

ROP

Start LeanFind (if LOP
appears hold STEP & LF until
ROP appears)

5

Lean the mixture at
approx. 10°/second
without pausing.

EGT

1520

FF

13.8

Flashing cylinder I.D. box
identifies that EGT increased
at least 15°F. EDM is now
looking for first EGT to peak.

6

Stop leaning when
a column begins
flashing. You will see

LEANEST

for one

second, followed by:

EGT

1545

FF

12.4

Flashing cylinder I.D. box
AND its column indicates
leanest cylinder. Due to
thermal inertia this will usually
be about -15°F down the lean
side of peak.

7

If you hold PEAK, the
values of EGT and
FF when peak was
found are displayed.

EGT

1560

FF

12.9

Captured peak EGT value and
peak FF are displayed.

8

If you tap PEAK, the
difference from peak
EGT is shown. Tap
again to return to the
peaked EGT value.

EGT

-90

FF

13.4

A useful mode for setting
mixture the desired degrees
rich of peak - no math
required! NOTE: Unit
remembers view last used.

9

Slowly enrich the
mixture noting that
EGT is returning to
peak. Stop enriching
at the desired EGT.
‘Peak’: best Econ.
‘ROP’ target: best
power.

EGT

1560

FF

12.9

EGT

1460

FF

13.6

(100º RICH OF PEAK)