For Your Safe Flight
Page 12
Section 3 - Displays and Controls
The EDM monitors engine temperatures, pressures and voltages, assists
in adjusting the fuel/air mixture, and helps diagnose engine
malfunctions. There are multiple components of the user interface:
Four front panel operating buttons below the bottom of the display.
RPM and MAP display in the upper left corner of the display
Scanner analog display including cylinder number and index square
in the lower left corner of the display
Scanner digital display for numeric readouts and messages at the
bottom left
Bar graph displays on the right half of the display
Control Buttons
Four operating buttons control all functions of the EDM. These buttons
may change labels depending on the current operating mode of the
EDM. The term tap is used to denote pressing a button momentarily.
The term hold is used to denote pressing and holding a button for five
seconds or longer. Button layout is shown below:
1st Button
In the Automatic mode, tapping the
STEP
button stops Scanner auto-
sequencing and changes to Manual mode. Each tap of the
STEP
button then displays the next measurement in the sequence. Holding
the
STEP
button sequences in reverse order.
In the LeanFind mode tapping the
EXIT
button will terminate the
LeanFind mode and change to the Automatic mode.
In the Program mode tapping the
NEXT
button will advance to the
next item.